Product Selection Guide Page 674 Product Selection Guide-11th Edition

PRODUCT INFORMATION PSG11 674 CENTRAL INVERTER SYSTEMS Power Systems www.lithonia.com Series Battery System VA rating Voltage 6 Output circuit breaker 8 Options EAC Emergency AC power system (blank) Lead-calcium, 10-year life LC20 Lead-calcium, 20-year life 1 NC Wet nickel cadmium (12 hr battery recharge not avail) 1 FTT Compact fast transfer FT Fast transfer 3FT 3-phase fast transfer ISS Interruptible 500 2 1000 2 1500 3 2000 2 2250 4 3000 4 3750 4 4800 1 6000 1 8000 1 10000 1 12500 1 16700 1 24000 5 33000 5 40000 5 50000 5 Input/output 120/120 3 277/277 3 277/120 4 120/120-277 4 277/120-277 4 208 5 480 5 208/120 4 240/120-240 4 (blank) None OB1 OB2 OB3 OB4 1 OB5 1 OB6 1 OB7 1 OB8 1 OB9 1 OB10 1 OB11 1 OB12 1 (blank) None Battery 12HR 12-hour battery recharge 1 Supervisory RMP Remote meter panel RSAP Remote summary alarm panel MBYP Maintenance bypass switch 4,7 XMBYP External maintenance bypass switch 1 Miscellaneous FSP Factory start-up program DFC Form "C" contacts N OFF Normally OFF output circuit 9 MODEM External modem for RS232 WBM Wall Mount Bracket 2 EAC FT EAC FTT EAC 3FT EAC ISS ORDERING INFORMATION Example: EAC 3FT 6000 208 OB2 DFC ADDITIONAL INFORMATION For additional product information, visit www.lithonia.com. 30 (76.2) 47 (119.4) 25 (63.5) EAC FT or EAC 3FT Notes 1 Not available with FTT. 2 Available on FTT only. 3 Not available with 3FT. 4 Available on FT and ISS only. 5 Available on 3FT only. 6 Consult factory for other voltage requirements. Special voltages may affect the weight, size and number of cabinets. (Anything other than 120/120 or 277/277). 7 Standard on 3FT. 8 Standard 20-amp normally on unless otherwise specified. 9 Normally offload cannot exceed 20% of total VA rating with any combination of HID loads. Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted. Specifications subject to change. 1 2 3 4 5 6 7 8 9 0 26 (66.0) 10 (25.4) 10 (25.4) 26 (66.0) 10 (25.4) 10 (25.4) 1 2 3 4 5 6 7 8 9 0 26 (66.0) 20 (50.8) 10 (25.4) System Diagram *Allow a minimum clearance of 39" front and 12" top. Intended Use An off-line AC power system for the emergency operation of LED, HID, incandescent, and fluorescent emergency lighting loads that provides full light output for 90 minutes of operation. Features ogy allows for universal compatibility time short-circuit protection, current-limiting, fused-battery protection, brownout protection, input circuit breaker Listings UL Listed (standard) for 90 minutes of emergency operation. LITHONIA LIGHTING EMERGENCY SYSTEMS Transfer Switch Battery Charger Battery Inverter Bypass Switch Maintenance Bypass Line AC No-Break Power Output Utility Power Line

Previous Page
Next Page