Product Selection Guide Page 664 Product Selection Guide-11th Edition

PSG11 664 EMERGENCY LIGHTING UNITS www.lithonia.com PRODUCT INFORMATION Industrial IND Indura Industrial Intended Use Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Unique, innovative design for a variety of light and heavy industrial applications and heavy commercial environments. Superiorperformance lamp heads are ideally suited for higher mounting heights. Perfect for pole and column mounting. Features mounting mounting, with accessory equipment, available on selected models steel mounting bracket shipped standard the unit. Maintenance is made easy by tool-less re-lamp, single tool entry, hinging front cover, printed circuit board mounting shelf and battery belt 6V, 12V and 24V Listings UL Listed. Meets UL924. Damp location listing. Cold weather (ULT) listing. NFPA 101, NEC and OSHA illumination standards. Series Housing color Lamp type (2 heads) Options 6 Volts IND618 18W IND654 54W IND100 100W 1 12 Volts IND1236 36W IND12354 54W IND12100 100W 1 IND12150 150W 2 IND12300 300W 2 IND12450 450W 2 24 Volts IND24100 100W 2 IND24450 450W 1,2 (blank) Gray front/navy back W White 6 Volts 12 Volts PAR36 Composite (blank) 9W/6V krypton (blank) 18W/24V incand H1206 12W/6V halogen H2024 20W/24V halogen H2006 20W/6V halogen PAR36 Sealed-Beam 12 Volts N5024S 50W/24V incand PAR36 Composite (blank) 9W/12V krypton H1212 12W/12V halogen H2012 20W/12V halogen PAR Sealed-Beam H3512S 35W/12V halogen H5012S 50W/12V halogen (blank) Damp location 50F to 104F (10C to 40C) XTRA Extra package. Features remote test, time delay and damp location 50F to 104F (10C to 40C) 3 SEL Select package. Features self-diagnostics, time delay, audible failure indication and damp location 50F to 104F (10C to 40C) PREM Premium package. Features high-temperature ni-cad battery (IND618 and IND1236 only) or high-temperature lead-calcium battery (IND12100 only), Self-diagnostics, time delay, audible failure indication and damp location. UL Listed for 32F to 131F (0C to 55C) 4,5 ULT Ultimate package. Features heater, thermostat and battery blanket with a high temperature ni-cad battery (IND618 and IND1236 only) or high- temperature lead-calcium battery (IND12100 only), self-diagnostics, time delay, audible failure indication and damp location. UL Listed for -40F to 131F (-40C to 55C) 4,5 WRS EL and self-diagnostics with FIDO wireless reporting system capibility 6 ORDERING INFORMATION Specifications subject to change. Example: IND1254 H2012 SEL ADDITIONAL INFORMATION For additional product information, visit www.lithonia.com. ELECTRICAL APPLICATION DATA TYPE AC INPUT 6 OUTPUT VOLTS OUTPUT WATTS VOLTS AMPS WATTS 1-1/2 HRS 2 HRS 3 HRS 4 HRS IND618 120 / 277 .163 / .069 19.6 / 19.11 6 18 13.5 9 6 IND654 120 / 277 .172 / .075 20.64 / 20.78 6 54 40 27 20 IND6100 120 / 277 .171 / .064 20.5 / 17.7 6 100 75 50 37 IND1236 120 / 277 .174 / .078 20.9 / 21.61 12 36 27 18 13 IND1254 120 / 277 .174 / .078 20.88 / 21.6 12 54 40 27 20 IND12100 120 / 277 .174 / .074 20.88 / 20.49 12 100 75 50 37 IND12150 120 / 277 .359 / .168 43.08 / 46.54 12 150 112 75 56 IND12300 120 / 277 .290 / .130 34.8 / 36.1 12 300 225 150 112 IND12450 120 / 277 .33 / .15 39.96 / 43.77 12 450 337 225 168 IND24100 120 / 277 .33 / .15 39.6 / 41.55 24 100 75 50 37 IND24450 120 / 277 .773 / .327 92.76 / 90.58 24 450 337 225 168 Large Housing 100W PREM or ULT (150W - 450W) Shipping weight: IND618 - 13 lbs. (5.9 kgs ) ND12150 - 45 lbs. ( 20.4 kgs) IND654 - 18 lbs. (8.2 kgs) IIND12300 - 72 lbs. (32.7 kgs) IND6100 - 23 lbs. (10.4 kgs) IND12450 - 75 lbs. (30.0 kgs) IND1236 - 18 lbs. (8.2 kgs) IND24100 - 27 lbs. (12.2 kgs) IND1254 - 18 lbs. (8.2 kgs) IND24450 - 75 lbs. (30.0 kgs) IND12100 - 27 lbs. (12.2 kgs) Small Housing (18-54W; 100W Standard, XTRA and SEL) Universal Mounting Bracket Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted. ACCESSORIES ORDER SEPARATELY ELA RTT Remote test transmitter 3 ELA IND CM1 Ceiling mount kit for IND618 11 ELA WG2M Wireguard - small (18W-100W) 8 ELA IND CM2 Ceiling mount kit for IND654/1236/1254 11 ELA WGLG Wireguard - large (150 - 450W) 8 ELA IND CM3 Ceiling mount kit for IND6100 11 ELA BS Banding Strap 9 ELA IND R3 Pre-pack to install third head 10 ELA IND PM Pendant mount kit for IND618/654/6100/1236/1254/12100/24100 10 FIDO Emergency wireless reporting system edge router (see FIDO specification for details) 18 (45.7) 16 (40.6) 13-1/4 (33.7) 16 (40.6) 12 (31.0) 8-5/8 (22.0) 9 (22.9) 12-1/2 (31.8) 8-3/8 (21.3) 1 (2.5) 2-1/4 (5.7) 3/8 (10.0) 8 (20.3) 3/4 (1.9) 1/4 (6.0) 2-1/4 (57.0) 2-3/4 (7.0) Notes 1 DL listed for indoor applications. 2 Not suitable for ceiling mount. 3 Must order a Remote transmitter (ELA RTT). One per job required. See spec sheet ELA-RTT-BS. 4 Only available on IND618, IND1236 and IND12100. 5 IND12100 PREM and IND12100 ULT come in a larger housing size. 6 Only available on IND12100 and IND12150. 7 Add 0.3 amps, 31W for models with ULT option. 8 See spec sheet ELA-WG. 9 Required for ceiling mount. Color is not a factor. See spec sheet ELA-IND-PM-CM-RHB-R3. 10 ELA IND PM accessory cannot be used with the IND12100 PREM or IND12100 ULT. Color is not a factor. See spec sheet ELA-IND-PM-CM- RHB-R3. 11 See spec sheet ELA-IND-PM-CM-RHB-R3. For additional lamp heads, remote fixtures, options and accessories, see pages 670-671. For application guidelines and fixture performance data, see pages 686-687. LITHONIA LIGHTING EMERGENCY SYSTEMS

Previous Page
Next Page