PRODUCT INFORMATION 263 PSG11 Series Mounting Voltage Lamp Qty Lamping Circuits Ballast options Options Emergency Finish Product Size HST124 2x4 FT HST122 2x2 FT HST114 1X4 FT G Grid F Flange 120 120V 277 277V MVOLT 120-277V 347 347V (Canada) 4 5 6 T8 32W (4 FT) 17W (2 FT) T5 28W (4 FT) 14W (2 FT) T5HO 54W (4 FT) 24W (2 FT) 1C 1 circuit 2C 2 circuits 3C 3 circuits 1C/1DM 1 normal ballast; 1 dimming circuit 2C/1DM 2 normal ballast; 1 dimming circuit 1DIM 1 dimming circuit 2DIM 2 dimming circuits 3DIM 3 dimming circuits GEB10RS Generic Electronic Rapid Start GEB10PS Generic Program Start DMHL3D Lutron Hi-Lume ADEZ Mark X Dimmer 5-100% Phase control ADZT Mark VII Dimmer 0-10V Low Voltage Dimmer PF Flange Mount only RM Flange Mount only RMP Row Mount Pattern (specify pattern/consult factory) GP1 One Green Lamp requires multi circuit GP2 Two Green Lamps requires multi circuit GLR Fast-Blo Fuse GMF Slo-Blo Fuse ALD Aluminum Door Painted BSD Brushed Stainless Door PSD Painted Stainless Door TGC T Grid Mounting Clips (T-grid only) B70A One lamp Bodine I48 Iota 1-2 lamp 350-700 lumens B501LP Bodine 1 lamp emergency B50 Bodine 2 lamp emergency B30 1-2 lamp emergency ballast GW Gloss White (Standard) AM Anti- Microbial White ORDERING INFORMATION Specifications subject to change. Example: HST124 G 120 6 T8 2C RM AM Intended Use Surgical troffers are designed to supplement the primary procedure lighting in the surgical theater. When grouped to surround the perimeter of the operating table, the symmetric/ asymmetric lens distributes light both downward and toward the surgical field, diminishing shadows and reducing eyestrain of the surgical team. A gasketed steel door with clean concealed hinge seals plenum contaminates from the surgical suite. For row-mounted flange applications, linking connectors are offered or end flanges may be conveniently removed to allow fixtures to be fastened to one another. Features alternative to conventional piano hinge from radiated electromagnetic emissions sensitive medical equipment from conducted emissions including green lamps ADDITIONAL INFORMATION For additional product information, visit www.healthcare-lighting.com. Notes 1 Special ballast require specified 120 or 277 voltage (no MVOLT or 347). 2 1x4 is 3 lamps; 2x2 and 2x4 are 3,4,5,6 lamps. 3 Consult factory for availability of 347V. 4 T5HO not available with 6 lamps. 5 Row mount adapter; specify pattern. Adapters shipped with fixtures. 6 Non-standard wiring contact factory. 7 PF and RM only with flange mount. 8 T8 ballast standard instant start, T5 ballast standard program start. OR/SURGICAL SUITE HST HEALTHCARE LIGHTING www.healthcare-lighting.com Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions (if provided) are shown in inches unless otherwise noted. 22 - 9/16" Flange 22 - 5/8" Grid 24" 4 - 5/8" 24" Grid 23 - 15/16" Flange 23 - 3/4" Grid 25 - 1/2" Flange 48" 22 - 9/16" Flange 22 - 5/8" Grid 4 - 5/8" 23 - 15/16" Flange 23 -3/4" Grid 49 - 1/2" Flange 48" Grid

Previous Page
Next Page