Product Selection Guide Page 262 Product Selection Guide-11th Edition

PRODUCT INFORMATION PSG11 262 Series Mounting Voltage Lamping Circuits Ballast options Options Emergency Finish Product Size HST524 2x4 FT HST522 2X2 FT G Grid F Flange 120 120V 277 277V MVOLT 120-277V 347 347V (Canada) T8 32W (4 FT) 17W (2 FT) T5 28W (4 FT) 14W (2 FT) T5HO 54W (4 FT) 24W (2 FT) 1C 1 circuit 2C 2 circuits 3C 3 circuits 1C/1DM 1 normal ballast; 1 dimming circuit 2C/1DM 2 normal ballast; 1 dimming circuit 1DIM 1 dimming circuit 2DIM 2 dimming circuits 3DIM 3 dimming circuits GEB10RS Generic Electronic Rapid Start GEB10PS Generic Program Start DMHL3D Lutron Hi-Lume ADEZ Mark X Dimmer 5-100% Phase control ADZT Mark VII Dimmer 0-10V Low Voltage Dimmer IP65 Sealed IP65 Rated PF Flange Mount only RM Flange Mount only RMP Row Mount Pattern (specify pattern/consult factory) GP1 One Green Lamp requires multi- circuit GP2 Two Green Lamps, requires multi circuit GLR Fast-Blo Fuse GMF Slo-Blo Fuse ALD Aluminum Door Painted BSD Brushed Stainless Door PSD Painted Stainless Door B70A One lamp Bodine I48 Iota 1-2 lamp 350-700 lumens B501LP Bodine 1 lamp emergency B50 Bodine 2 lamp emergency B30 1-2 lamp emergency ballast GW Gloss White (Standard) AM Anti- Microbial White ORDERING INFORMATION Specifications subject to change. Example: HST524 F 120 T8 2C RM OR/SURGICAL SUITE Intended Use Recognized by the Illuminating Engineering Society for its in- novative design, the Surg5 is the energy-efficient alternative to standard 6-lamp surgical troffers. The custom-designed optics allow 5 lamps in this fixture to deliver lighting performance that is equivalent to typical 2x4 recessed troffers employing 6 lamps. Thats a 17% energy savings per fixture. But the benefits of this fixture dont end with energy savings. Maintenance of typical 6-lamp troffers requires removal of all lamps and reflectors to access ballasts. This increases the likelihood of lamp breakage in the surgical suite. The Surg5 design allows for the ballast to be replaced without removing the lamps and reflectors. Of course, there is also one fewer lamp to carry up the ladder when it is time for re-lamping. All of these innovations translate to savings in maintenance time. Features troffers (17% energy savings!) installation SURG5 Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions (if provided) are shown in inches unless otherwise noted. ADDITIONAL INFORMATION For additional product information, visit www.healthcare-lighting.com. Notes 1 Special ballast require specified 120 or 277 voltage (no MVOLT or 347). 2 1x4 is 3 lamps; 2x2 and 2x4 are 3,4,5,6 lamps. 3 Consult factory for availability of 347V. 4 T5HO not available with 6 lamps. 5 Row mount adapter; specify pattern. Adapters shipped with fixtures. 6 Non-standard wiring contact factory. 7 PF and RM only with flange mount. 8 T8 ballast standard instant start, T5 ballast standard program start. Surg5 HEALTHCARE LIGHTING www.healthcare-lighting.com 24" 23 - 3/32" 4 - 1/2" Flange 4 - 7/8" Grid 25 - 1/4" Flange 23 - 3/4" Grid 24" Flange 23 - 3/4" Grid 24" Flange 23 3/4" Grid 49 - 1/4" Flange 47 - 3/4" Grid 23 - 3/32" 48" 4 -1/2" Flange 4 -7/8" Grid

Previous Page
Next Page