Product Selection Guide Page 233 Product Selection Guide-11th Edition

PRODUCT INFORMATION 233 PSG11 Series Exam Type Mounting Voltage Diffuser Ambient lamping Ambient control Ambient circuits Options Finish Product Size HPT22LB 2X2 FT MA Motorized (includes LVM) FA Non-Motorized G Grid F Flange 120 120V 277 277V TAI Translucent Acrylic (Standard) PAI Perforated Acrylic Insert (Recommended for Patient Rooms) 2ACF55 2x55W Biax 3ACF55 3x55W Biax 2ACF40 2x40W Biax 3ACF40 3x40W Biax LVA - Low Voltage Controller (FA adder) LV1A - LVC with J-box and Pillow Switch (FA) LVMJPS - 1-gang J-box with pillow switch (MA Only) LVMEC - Remote pendant exam control (MA only) LVMJPSEC - Both LVMJPS and LVMEC (MA only) SX - No Switch 1C 1 Circuit ambient 2C 2 Circuit - bi-level ambient ADEZ Mark X Dimming ballast 5-100% phase control ADZT Mark VII Dimming ballast 0-10V low voltage dimmer LCR LED Chart Light on Right LCL LED Chart Light on Left CR11 MR11 Chart Light on Right CL11 MR11 Chart Light on Left GLR Fast-Blo Fuse GMF Slo-Blo Fuse LNL LED Night Light NFL Fluorescent Night Light GW Gloss White (Standard) AM Anti- Microbial White ORDERING INFORMATION Specifications subject to change. Example: HPT222LB MA F 120 TAI 2ACF55 1C LCL Intended Use The louvered patient lighting section of the fixture is designed for bi-level switching so that the patient can easily select light- ing that is comfortable for their purpose. Light levels can be controlled via the nurse call system, if wired to the low voltage controller in the fixture, or using a separate pendant pillow switch (optional). A center basket style is also offered as an alternative to the louvered design. (Consult factory.) Features control, included when head is positioned throughout range of motion Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions (if provided) are shown in inches unless otherwise noted. ADDITIONAL INFORMATION For additional product information, visit www.healthcare-lighting.com. Notes 1 Three each 75W MR16 exam lamps included. 2 MA option comes with 4-Circuit Low Voltage Controller and 2-gang wall plate (LVM). 3 LVA and LV1A with FA only - 2 circuit low voltage switch. 4 JPS and EC with Motorized Exam only; when nurse call system unavailable. 5 Ambient dimming only with SX option; controlled by others. 6 Program start ballasts standard. 7 For HPT222LB (2x2), ambient section has louvers with acrylic overlay. CEILING OMNILUME 2x2 Omnilume HEALTHCARE LIGHTING www.healthcare-lighting.com 23 - 5/8" Grid 23 - 23/32" Flange 22 -1/2" 5 -7/8" Grid 5 - 5/8" Flange 23 - 3/4" 25 - 1/8" Flange 23 5/8" Grid

Previous Page
Next Page