Product Selection Guide Page 138 Product Selection Guide-11th Edition

Luminaire Number of lamps in cross section Lamp type Shielding Luminaire row length Maximum section length Voltage Ballast type Number of emergency modules CLM9 2 28T5 28W T5 54T5HO 54W T5HO COA Crenulated opal acrylic X FT 4' increments R4 4' section(s) R8 8' section(s) R12 12' section(s) 120 277 347 (not available with T5) GEB10 <10% THD Electronic ADEZ* Advance Mark ADZT* Advance 7 0-10V dim DMHL3D* Lutron Hi-Lume dim *Not available in 347V. Reference Ballast Wizard on website or consult factory for other options. (blank) None 1SE 1 section 2SE 2 sections XSE X sections Emergency type 1 Switching Lamp color Mounting type Overall suspension Options (blank) None EC Emergency circuit EL 2 Emergency battery pack (Not available in 347V) EN 2 Emergency battery pack w/night light circuit (Not available in 347V) 1 Emergency type is installed in last 4' of luminaire sections. Separate feed required unless ELS or ELS2 is specified. 2 Option EL or EN (Battery Pack) is: a. not permitted with dimming b. must be in the same section as the lamp being operated c. not permitted in a 4' section d. limited to one battery pack per section SCT Single circuit ALC* Alternate lamping module circuit *ALC not available with dimming L/LP No lamp LP830 3000K 80+ CRI LP835 3500K 80+ CRI LP841 4100K 80+ CRI Available with T5 only: LP830P 3000K 80+ CRI Premier LP835P 3500K 80+ CRI Premier LP841P 4100K 80+ CRI Premier Reference Lamp Chart on website or consult factory for other options. F1 T-Bar ceiling (univeral mounting bracket F1A/ T-Bar ceiling (UMB with integrated J-Box) F2/ Hard ceiling (horizontal J-Box) 12 12" 15 15" 18 18" 21 21" 24 24" XX XX" Overall suspension is measured from ceiling to bottom of luminaire. ACG Adjustable cable grippers BLK Black cord, cord manager and canopy DL Damp location label GLR Fusing (fast blow) GMF Fusing (slow blow) MCS Matching feed canopy at support NEPP5D Light enabled control module per row/zone OJB Offset junction box SLP Sloped ceiling (for 10-45, must be specified along with F2, ACG and OJB options) XXXX Smart luminaire (see note above) PRODUCT INFORMATION PSG11 138 CONTRAIL Linear Suspended www.peerlesslighting.com PEERLESS Example: CLM9 2 28T5 COA 40FT R8 277 GEB10 SCT LP835 F1/18 ORDERING INFORMATION Specifications subject to change. ADDITIONAL INFORMATION For additional product information, visit www.peerlesslighting.com. CLM9 Indirect-Direct (2) T5, T5HO 6" 3" Corner Assembly Tenon Assembly with integrated sensor CLM9 4' 12' 8' Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions (if provided) are shown in inches unless otherwise noted. Configurations Mitered tenon corner and tenon connectors available for suspended configurations. Additional pattern connector details available at PeerlessLighting.com. Construction Die-formed, pre-painted steel housing. Extruded aluminum fillers. Die-cast aluminum end caps. Highly specular aluminum end plates. Shielding GrateOptic curved, crenulated diffuser is extruded opal acrylic. Reflectors Die-formed, highly specular aluminum reflector has a minimum 98% reflectance. Finish Fine-textured, white polyester powder paint is standard on the fillers and end caps. Electrical Specify 120V, 277V or 347V. Pre-wired with 16AWG luminaire wires. For special circuiting or wire gauge, consult factory. Plug- in electrical connectors included. UL and cUL Listed. Luminaire Length 4', 8', and 12' individual luminaire sections for nominal suspen- sion spacing of 4', 8' and 12'. Add 3 5/8" for each end cap to determine total luminaire length. Using internal joiners, 4', 8' and 12' sections can be joined to form longer length luminaires. Smart Luminaire Integrated occupancy sensing, daylight detection and/or network control available. Limitations may apply, see luminaire specification on website for details and option code.

Previous Page
Next Page