Product Selection Guide Page 1081 Product Selection Guide-11th Edition

1081 PSG11 PRODUCT INFORMATION MODULAR SYSTEMS Quick-Flex www.relocwiring.com RELOC WIRING SOLUTIONS Intended Use Carries power with the use of the Quick-Flex extender (QE). Ideal for powering downlighting, track light feeds, exit sign. Can be used in place of two existing products, the Quick-Flex splitter (QS) and drop (QD). Controls-Enabled Wiring multi-circuit 0-24V dimming (0-10V or DALI) Listings UL Listed to U.S. and Canadian safety standards. Built to UL Standard 183 for Manufactured Wiring Systems and suitable for air handling spaces above grid ceiling as described in NEC 300.22(C). Meets NEC requirements for redundant ground paths for patient care areas in healthcare facilities. QPT Quick-Flex Power Tee ADDITIONAL INFORMATION For additional product information, visit www.relocwiring.com. Notes 1 Top portion not used on standard product. 2 Standard lengths listed. Consult factory for custom lengths. 3 RRL option will require the fixture description to have a wiring instruction. See page 113 for fixture ordering information. ( i.e. RRLA, RRLAE ) PRODUCT INFORMATION Quick-Flex Intended Use Male drop cable allows miscellaneous devices (i.e. exits or power availability) to become part of the Quick-Flex system. Listings UL Listed to U.S. and Canadian safety standards. Built to UL Standard 183 for Manufactured Wiring Systems and suitable for air handling spaces above grid ceiling as described in NEC 300.22(C). Meets NEC requirements for redundant ground paths for patient care areas in healthcare facilities. QD Quick-Flex Drop Cable Series/ Voltage Conductors/Length 2 Options QPT 1 120 120V 277 277V 347 347V 12/2G Two 12AWG conductors plus one 12AWG ground 01 1 ft 12/3G Three 12AWG conductors plus one 12AWG ground 03 3 ft 05 5 ft 09 9 ft 15 15 ft 19 19 ft (blank) Not required HCF Meets healthcare facility requirements RRL Reloc Ready Luminaire 3 ORDERING INFORMATION Specifications subject to change. Example: QPT277 12/3G01 ADDITIONAL INFORMATION For additional product information, visit www.relocwiring.com. Notes 1 Standard lengths listed. Consult factory for custom lengths. 2 RRL option will require the fixture description to have a wiring instruction. See page 113 for fixture ordering information. (i.e. RRLA, RRLAE) Series/ Voltage Conductors/Length 1 Options QD 120 120V 277 277V 347 347V 12/2G Two 12AWG conductors plus one 12AWG ground 01 1 ft 12/3G Three 12AWG conductors plus one 12AWG ground 03 3 ft 05 5 ft 09 9 ft 15 15 ft (blank) Not required HCF Meets healthcare facility requirements RRL Reloc Ready Luminaire 2 ORDERING INFORMATION Specifications subject to change. Example: QD277 12/3G09

Previous Page
Next Page