Product Selection Guide Page 1080 Product Selection Guide-11th Edition

PSG11 1080 PRODUCT INFORMATION MODULAR SYSTEMS Quick-Flex www.relocwiring.com RELOC WIRING SOLUTIONS Example: QSD277 2LEVEL09 Intended Use The Quick-Flex Switch Drop, located above the primary switch location, introduces local switching to the Quick-Flex system. It provides local switched power for fixtures as well as the ability to carry on unswitched power through the use of a Quick-Flex Extender (QE). Features with different voltages thermoplastic insulation rated 600V grounding conductor switch location single-level dimming devices Quick-Flex system Listings UL Listed. Built to UL Standard 183 for Manufactured Wiring Systems and suitable for air handling spaces above grid ceiling as described in NEC 300.22(C). Listed and labeled to comply with Canadian Standards. QSD Quick-Flex Switch Drop ADDITIONAL INFORMATION For additional product information, visit www.relocwiring.com. ADDITIONAL INFORMATION For additional product information, visit www.relocwiring.com. Notes 1 Standard lengths listed. Consult factory for custom lengths. 2 HCF is available with 2LEVEL and 1LEVEL/N conductors only. Intended Use Male/female cable that provides additional length anywhere within the Quick-Flex system. Features healthcare facilities Controls-Enabled Wiring system for Sensor Switch, nLight LC&D X-Point fixture level control Listings UL Listed and built to UL Standard 183 for Manufactured Wiring Systems and suitable for air handling spaces above grid ceiling as described in NEC 300.22(C). Listed and labeled to comply with Canadian Standards. Meets NEC requirements for redundant ground paths for patient care areas in healthcare facilities (HCF option). QE Quick-Flex Extender Example: QE277 12/3G15 Notes 1 Standard lengths listed. Consult factory for custom lengths. 2 CAT5 length must be at least two feet longer than QE length. If QD or QPT is used for fixture CAT5 length must include their length in addition to the QE and 2 ft. Series/ Voltage Conductors/Length 1 Options QSD 120 120V 277 277V 347 347V ILEVEL Two 12AWG conductors plus one 12AWG ground 05 5 ft 2LEVEL Four 12AWG conductors plus one 12AWG ground 07 7 ft 1LEVEL/N Two 12AWG conductors plus 12AWG ground and 12 AWG neutral 09 9 ft 13 13 ft 15 15 ft (blank) Not required HCF Meets healthcare facility requirements 2 Series/ Voltage Conductors/Length 1 Controls Wiring Options Options QE 120 120V 277 277V 347 347V 12/2G Two 12AWG conductors plus one 12AWG ground 05 5 ft 12/3G Three 12AWG conductors plus one 12AWG ground 07 7 ft 11 11 ft 15 15 ft 25 25 ft 31 31 ft (blank) Not required CAT5_ Pre-terminated & tested CAT5 cable attached QFE, specify length 2 (blank) Not required HCF Meets healthcare facility requirements ORDERING INFORMATION Specifications subject to change. ORDERING INFORMATION Specifications subject to change. PRODUCT INFORMATION Quick-Flex

Previous Page
Next Page