Product Selection Guide Page 1079 Product Selection Guide-11th Edition

1079 PSG11 PRODUCT INFORMATION MODULAR SYSTEMS Quick-Flex www.relocwiring.com RELOC WIRING SOLUTIONS QFC Quick-Flex Fixture Cable ADDITIONAL INFORMATION For additional product information, visit www.relocwiring.com. Notes 1 Standard lengths listed. Consult factory for custom lengths. 2 CAT5 length must be at least 2 ft. longer than QFC length. (i.e. QFC2TI 12/3611 CAT513) 3 UL Listed for auto ground. Use G option only when required by local codes. 4 G option required for Canada. 5 G option required when ordering HFC. 6 RRL option will require the fixture description to have a wiring instruction. See page 113 for fixture ordering information. ( i.e. RRLA, RRLAE ) Example: QFC277 12/3G11 G HCF Series/Voltage Conductors/Length 1 Controls Wiring Options Options QFC 120 120V 277 277V 347 347V 12/2G Two 12AWG conductors plus one 12AWG ground 12/3G Three 12AWG conductors plus one 12AWG ground 05 5 ft 07 7 ft 09 9 ft 11 11 ft 13 13 ft 15 15 ft (blank) Not required CAT5_ Pre-terminated & tested CAT5 cable attached to QFC, specify length 2 (blank) Not required G 18AWG ground lead dropped to fixture 3.4 HCF Meets healthcare facility requirements 5 RRL RELOC Ready Luminaire 6 Notes 1 Standard lengths listed. Consult factory for custom lengths. 2 CAT5 length must be at least 2 ft. longer than QSFC length. 3 G option required for Canada. 4 G option required when ordering HFC. 5 RRL option will require the fixture description to have a wiring instruction. See page 113 for fixture ordering information. (i.e. RRLA, RRLAE) 6 UL Listed for auto ground. Use G option only when required by local codes. ADDITIONAL INFORMATION For additional product information, visit www.relocwiring.com. Example: QSFC277 12/3G15 CAT517 Series/ Voltage Conductors/Length 1 Controls Wiring Options Options QSFC 120 120V 277 277V 347 347V 12/2G Two 12AWG conductors plus one 12AWG ground 09 9 ft 12/3G Three 12AWG conductors plus one 12AWG ground 11 11 ft 13 13 ft 15 15 ft (blank) Not required CAT5_ Pre-terminated & tested CAT5 cable attached to QSFC, specify length 2 (blank) Not required G 18AWG ground lead dropped to fixture 3,6 HCF Meets healthcare facility requirements 4 RRL RELOC Ready Luminaire 5 ORDERING INFORMATION Specifications subject to change. Intended Use Male/female cable that provides power from fixture to fixture in the Quick-Flex system. Features spacing requirements facilities Controls-Enabled Wiring Flex system for Sensor Switch, nLight LC&D X-Point fixture level control Listings UL Listed, and built to UL Standard 183 for Manufactured Wiring Systems and suitable for air handling spaces above grid ceiling as described in NEC 300.22(C). Listed and labeled to comply with Canadian Standards. Meets NEC requirements for redundant ground paths for Patient Care Areas in healthcare facilities (HFC option). ORDERING INFORMATION Specifications subject to change. Intended Use Combination of converter (QC) and fixture cable (QFC). Wires directly into homerun junction box, switch box or junction box above switch location; provides power to the first fixture from that location. Features spacing requirements easy installation into a 1/2" trade size knockout facilities Controls-Enabled Wiring system for Sensor Switch, nLight, LC&D X-Point fixture level control Listings UL Listed and built to UL Standard 183 for Manufactured Wiring Systems and suitable for air handling spaces above grid ceiling as described in NEC 300.22(C). Listed and labeled to comply with Canadian Standards. Meets NEC requirements for redundant ground paths for patient care areas in healthcare facilities (HCF option). QSFC Quick-Flex Starter Fixture Cable PRODUCT INFORMATION Quick-Flex

Previous Page
Next Page