1073 PSG11 PRODUCT INFORMATION MODULAR SYSTEMS System 820 www.relocwiring.com RELOC WIRING SOLUTIONS Intended Use Male/female cable that provides power from fixture to fixture. The SSC attaches directly into the access plate or through 1/ 2'' trade-size knockout. Features requirements (HCF option) Controls-Enabled Wiring (0-10V or DALI) Sensor Switch, nLight LC&D X-Point fixture level control System 820. The connector will be factory attached to the cable. The matting connector wil be pre-wired based on the appropriate wiring instruction selection for the luminaire. See page 113 for ixture ordering information Listings UL Listed. Listed and labeled to comply with Canadian Standards. Meets NEC requirements for redundant ground paths for patient care areas in healthcare facilities (HCF option). ADDITIONAL INFORMATION For additional product information, visit www.relocwiring.com. ADDITIONAL INFORMATION For additional product information, visit www.relocwiring.com. Series Voltage Conductors Factory keying Length 1 Controls Wiring Options Options SSC 120 120V 277 277V 347 347V D Three E Four F Five U 05 5 ft 07 7 ft 09 7 ft 11 11 ft 13 13 ft 15 15 ft (blank) Not required C12S Integrated CI, CII rated line voltage and signal wires 2 CAT5_ Pre-terminated & tested CAT5 cable attached to SSC, specify length 3 (blank) Not required 2N Two circuit, two neutral 4 HCF Meets healthcare facility requirements 4 G Ground wire 5,6 RRL RELOC Ready Luminaire 7 SSC Standard Selector Cable PRODUCT INFORMATION System 820 Intended Use Male/female cable that provides additional length anywhere throughout the 820 system. Features spacing requirements facilities (HCF option) Controls-Enabled Wiring wires (0-10V or DALI) for Sensor Switch, nLight LC&D X-Point fixture level control Listings UL Listed. Listed and labeled to comply with Canadian Standards. Meets NEC requirements for redundant ground paths for patient care areas in healthcare facilities (HCF option). Series Voltage Conductors Factory keying Length 1 Controls Wiring Options Options CE 120 120V 208 208V 240 240V 277 277V 347 347V 480 480V D Three E Four F Five U 05 5 ft 07 7 ft 09 7 ft 11 11 ft 13 13 ft 15 15 ft 19 19 ft 21 21 ft 25 25 ft 31 31 ft 35 35 ft (blank) Not required C12S Integrated CI, CII rated line voltage and signal wires 2 CAT5_ Pre-terminated tested CAT5 cable attached to CE, specify length 3 (blank) Not required 2N Two circuit, two neutral 4 HCF Meets healthcare facility requirements 4 IGW Isolated ground wire 5 Example: SSC 120 F U 11 G ORDERING INFORMATION Specifications subject to change. Example: CE 277 F U 11 ORDERING INFORMATION Specifications subject to change. Notes 1 Standard lengths listed. Consult factory for custom lengths. 2 C12S available with D conductor only. 3 CAT5 length must be at least 2 ft. longer than CE length. If DC or PT is used to power fixtures, include their length in the CAT5 length required and two feet. 4 Available with F conductor only, and 120V, 277V and 347V. 5 IGW available with 120V, E and F conductors only. Notes 1 Standard lengths listed. Consult factory for custom lengths. 2 C12S available with D conductor only. 3 CAT5 option must be at least 2 ft. longer than SSC. 4 Available with F conductor only. 5 G option must be included with HCF option. 6 G option required for use in Canada. 7 RRL option will require the fixture description to have a wiring instruction. See page 113 for fixture ordering information. (i.e. RRLA, RRLAE) CE Cable Extender

Previous Page
Next Page