Product Selection Guide Page 1065 Product Selection Guide-11th Edition

1065 PSG1 1 PRODUCT INFORMATION Intended Use An economic alternative to the site-constructed conduit and wire or metal cable (MC) normally used from the panel to a distribution point or between pull boxes. When combined with the distribution box primary (DBP) the RMC is a complete modular solution. Features 6AWG-12AWG neutral conductors the user to order the specific combination of conductors required and install it directly at the site NEC 300.22 (c) Listings Assembly of all UL Listed components. BACK TO THE PANEL PRODUCT INFORMATION Main Distribution Intended Use A modular junction box that allows transition from oversized conductors used in the RELOC mainrun cable (RMC) to the RELOC modular wiring system. Available in two sizes, the DBP can be used in an open ceiling, above a hung ceiling, and below a raised floor, including low-profile raised floors. Features 12 RELOC ports) available OnePass attached and all ports and conductors labeled to show circuit assignments to be field-wired to the DBP per RELOC port NEC 300.22 (c) Listings UL and cUL Listed. DBP Distribution Box Primary ADDITIONAL INFORMATION For additional product information, visit www.relocwiring.com. Main Distribution www.relocwiring.com RELOC WIRING SOLUTIONS RMC RELOC Mainrun Cable Example: DBP 120 4CD Series Voltage Output connection 2 Options DBP Distribution box primary 120 120V 208 208V 1 220 220V 1 240 240V 1 277 277V 347 347V 480 480V 1 _CD System 820 circuit distributor 3,4 _OC OnePass converter 3,4 _QC Quick-Flex converter 1,5,6 2N Two hots and neutrals IGW Isolated ground wire PB Pull box 7 LP Low-profile box ORDERING INFORMATION Specifications subject to change. ADDITIONAL INFORMATION For additional product information, visit www.relocwiring.com. Notes 1 Available in 10-foot increments. 2 Specify number of hot conductors (1-12) in blank. 3 Specify number of neutral conductors (1-6) in blank. 4 Specify number of ground conductors (1 or 2) in blank. 5 Specify system distribution port type for (CD = 820 System; QC = QuickFlex; OC=OnePass) and specify voltage (120, 277, 480, 208, 240) in blank. Example: PB4OC277D or 4QC120F. 6 Configuration can note be used with Quick-Flex QC. 7 Consult a factory for custom requirements. 8 If RMC with Pull Box required, standard RMC with DBP (Distribution Box) is needed to complete the modular run. Series/Number of channels Length 1 Hot conductor properties 2 Neutral conductor properties 3 Ground conductor properties 4 RMC RELOC mainrun cable 500-300 Cable armor in feet 8/_H 8-gauge wire with _hot conductors 10/_H 10-gauge wire with _hot conductors 12/_H 12-gauge wire with _hot conductors 6/_N 6-gauge wire with _neutral conductors 8/_N 8-gauge wire with _neutral conductors 10/_N 10-gauge wire with _neutral conductors 12/_N 12-gauge wire with_neutral conductors 8/_G 8-gauge wire with ground conductors 10/_G 10-gauge wire with ground conductors 12/_G 12-gauge wire with ground conductor Panel end lengths Options Distribution box port configuration 5,7 Pull box port configuration 5,8 (blank) 10 ft A 20 ft B Custom (blank) None T Pull box (blank) Not required 12__D 12 Circuits, 4 Neutrals, 1 Circuit per port 9__D 9 Circuits, 3 Neutrals, 1 Circuit per port 6__D 9 Circuits, 9 Neutrals, 1 Circuit per port 9__DN 9 Circuits, 9 Neutrals, 1 Circuit per port 6__DN 6 Circuits, 6 Neutrals, 1 Circuit per port 4__DN 8 Circuits, 8 Neutrals, 2 Circuits per port 5__F 15 Circuits, 1 Neutral, 3 Circuits per port 6 4__F 12 Circuits, 1 Neutral, 3 Circuits per port 6 3__ F 9 Circuits, 1 Neutral, 3 Circuits per port 6 2__ F 6 Circuits, 1 Neutral, 3 Circuits per port 6 4__F 12 Circuits, 4 Neutrals, 3 Circuits per port 6 3__ F 9 Circuits, 3 Neutrals, 3 Circuits per port 6 2__F 6 Circuits, 2 Neutrals, 3 Circuits per port 6 (blank) Not required PB4__D 4 Circuits, 1 Neutral, 1 Circuit per port PB6__ D 6 Circuits, 1 Neutral, 1 Circuit per port PB8__ D 8 Circuits, 1 Neutral, 1 Circuit per port PB4__ F 8 Circuits, 1 Neutral, 2 Circuits per port PB6__ F 12 Circuits, 1 Neutral, 1 Circuit per port PB8__ F 16 Circuits, 1 Neutral, 2 Circuits per port ORDERING INFORMATION Specifications subject to change. Example: RMC 130 10/8H 10/8N 10/1G 4CD12ODN Notes 1 Not available with IGW and 2N options. 2 Minimum output ports available is 2. Maximum output ports available is 12. Specify number of ports per box in blank. 3 CD and OC - three circuits available for 120V, 277V and 347V. Three phase circuit or two circuit available for 208V, 220V, 240V, and 480V. 4 CD and OC - 120V, 277V and 347V two circuits available with 2N option only. 5 QC - two circuits for 120V, 277V and 347V. 6 QC - not available in 208V, 220V, 240V and 480V. 7 Maximum number of output connections available with PB option is 8.

Previous Page
Next Page