Product Selection Guide Page 1058 Product Selection Guide-11th Edition

PRODUCT INFORMATION PSG11 1058 TECHNICAL INFORMATION POWER SENTRY EMERGENCY BALLASTS Lamp/Ballast Compatibility Spacing Guidelines Technical Information POWER SENTRY www.powersentrysafety.com POWER SENTRY LAMP BALLAST COMPATIBILITY - UL LISTED PRODUCTS LAMP TYPE WATTAGE PS300QD PSQ500QD PS600QD PS1400QD PSL400 PSL550 PSL600 PS600C PS3000 PS48 PSDL1 PSDL2 PSDL3 24" - 48" T5 14-28 1 24" - 48" T5H0 24-54 1 U-lamp T8 16-32 1 1, 2 1 1,2 24" - 48" T8 17-32 1 1, 2 1 3 1,2 48" - 60" T8 32-40 1, 2 1 60" - 96" T8 40-59 1 96" T8HO 86 Circline T9 20-40 1 U-lamp T12 34-40 1 1, 2 1 1,2 24" - 48" T12 20-40 1 1, 2 1 3 1,2 60" - 96" T12 50-75 1 24" - 48" T12H0 35-60 1 60" - 96" T12HO 70-110 1 24" - 48" T12VHO 74-115 1 60" - 96" T12VHO 135-215 1 PL Twin-Tube (2-Pin) 9-13 1 PL Quad-Tube (2-Pin) 13-26 1 1, 4 1 PL Twin-Tube (4-Pin) 9-13 1 1,2 1 PL Quad-Tube (4-Pin) 13-26 1 1, 2 1 1,2 Triple-Tube (4-Pin) 18-32 1 1, 2 1 1,2 Triple-Tube (4-Pin) 42 1 1,2 1 Long Compact (4-Pin) 18-40 1 1,2 Long Compact (4-Pin) 36-55 1 POWER SENTRY SPACING GUIDELINES 5,6,7 2X2 2X4 TURRET INDUSTRIALS 2GT8 2 U316 2SP8 2 U316 2AV 2 CF40 2PM3N 2 U316 2PMO 2 U31 2GT8 3 32 2SP8 3 32 2AV3 3 32 2PM3N3 3 32 2PMO3 3 32 AF 2 96 CATALOG NUMBER 1FC AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. CORRIDOR PS300QD 18 14 20 14 14 12 17 14 17 13 20 16 24 16 18 14 21 16 21 16 -- -- PSQ500QD 32 18 31 18 24 17 27 18 27 16 32 22 35 22 28 20 32 22 32 19 -- -- PS600QD 39 21 40 20 29 21 35 20 28 17 40 25 43 24 34 25 40 25 40 20 -- -- PS1400QD 58 29 54 30 53 29 48 29 42 21 47 31 57 25 59 32 53 31 43 8 25 -- -- OPEN OFFICE PS300QD 16 13 16 13 14 12 14 12 14 12 16 13 16 14 13 11 17 14 18 14 -- -- PS500QD 26 17 27 17 24 16 24 17 23 17 26 17 29 17 21 15 27 18 29 17 -- -- PS600QD 32 19 33 18 29 18 29 16 28 19 32 18 35 19 26 17 34 20 35 18 -- -- PS1400QD 26 8 25 47 24 47 26 38 22 26 8 22 47 24 47 24 47 25 45 27 33 8 22 -- -- INDUSTRIAL PS1400QD -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 25 23 Notes 1 One-lamp emergency operation for one-, two-, three- or four-lamp ballasts. 2 Two-lamp emergency operation for two-, three- or four-lamp ballasts. 3 One-lamp, two-hour emergency operation for two-, three- or four-lamp ballasts. 4 2LP option required for two-lamp emergency operation in fixtures with two or more lamps. 5 All spacings are intended to be guidelines. Results will vary if application deviates from dimensions or assumptions stated below. 6 Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes a 1.0 FC minimum requirement. Assumes 3 T8 lamps in each fixture, 6' wide path of egress and a 9' ceiling height (exception: 18' ceiling on industrials). 7 Assumptions to arrive at these spacings: Open office dimensions/ reflectances: 100' L x 80' W x 9'H with 80/50/20 reflectances. Corridor dimensions/reflectances: 100' L x 8' W x 9' H with 80/50/20 reflectances. Industrial dimensions/reflectances: 200' L x 200 W x18 H with 10/10/10 reflectances. 8 Limited spacing due to 40:1 max-to-min ratio requirement by NFPA 101. = Available

Previous Page
Next Page